Electrical Test Equipment Rental Companies

Where do you rent your electrical test equipment?   Oftentimes, you may not have a test set that you may need. There are multiple reasons why this may be the case. Those of us who regularly work in the electrical testing field, know how expensive equipment is. A primary current injection test set may sell […]

Read More…

Why is NETA important?

Many people do not know what NETA is. Before I can explain my views of NETA, the following statement is directly from NETA’s website. What is NETA? The InterNational Electrical Testing Association (NETA) is an organization that serves the electrical testing industry by offering accreditation of third-party electrical testing firms, certifying electrical testing technicians, producing […]

Read More…

Sulfur hexafluoride (SF6)

What is SF6? It’s an inert, colorless, odorless and non-flammable gas.  Sulfur hexafuoride is about 5 times denser than air, meaning it’s heavier. If you were to fill a fish tank with SF6, you could treat the gas as if you were pouring water into a fish tank. It will collectively stay within the fish tank. It is […]

Read More…

General Electric 15kV MagnaBlast Troubleshooting

The power company, or you, decide you need to de-energize a circuit. You rack out and remove your trusted 1960’s vintage breakers, of course you are suited up in the proper level PPE (Personal Protective Equipment). You then dust off your vintage ground and test device and install it in the cubicle. Connect the motor […]

Read More…

The Importance of Acceptance Testing

Before we can begin to talk about “Acceptance Testing”, you may or may not understand the phrase. Acceptance Testing pertains to all new electrical components. These are either purchased from a distributor, or even a manufacturer, but have never been put into “service”, i.e. energized. When a building is being remodeled, or even rebuilt, a […]

Read More…

Medium Voltage Cable / 15kV Terminations

Medium Voltage Cables Electrical wire is an integral part of our lifestyle. Whether you care to notice or not, copper/aluminum conductors are everywhere. They provide power to every business and home that wishes to be connected. Most of the time, people who aren’t in the electrical trade, tend to see overhead power lines. Those consist […]

Read More…

Effects of Frozen Moisture in Oil Filled Equipment

Good Old, Quality H2O! Recently, the temperatures have been rather cold in the Washington DC area. We hit a week of temperatures below 20°F. Yes, I know; not very cold when compared to our northern states or Canada. But it still brought up some very good talking points. Do you test equipment below 0°C (32°F)? […]

Read More…

Transformer Snubber Assembly

What is a Transformer Snubber? It is a set of capacitors, surge arresters, fuses, and resistors typically found on medium voltage dry type transformers. What are Snubbers designed for? The main application has been to reduce damage to transformers during energizing applications. Energizing medium voltage transformers produces transient voltages. These transient voltages are a cause […]

Read More…

General Electric Multilin Protective Relaying

Multilins SR745 & SR750 Model Power Supply Issues: Recently, I have been tasked to perform some relay testing on multiple General Electric SR relay models. But in particular, the issues experienced have been with the original model SR745 (Transformer Protection Relay) and the SR750 (Feeder Protection Relay) models. Here are examples of the Original and […]

Read More…